VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 1
READ ALL INSTRUCTIONS CAREFULLY
BEFORE STARTING THE INSTALLATION
OR OPERATING THE STOVE. FAILURE
TO FOLLOW INSTRUCTIONS MAY RE-
SULT IN PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH.
DO
NOT
USE THIS STOVE IN A
MOBILE HOME, MANUFACTURED HOME,
TRAILER OR TENT –
NO EXCEPTIONS!
This stove meets
U.S. Test Standard:
UL 1482-1996
SAFETY INSTRUCTIONS
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PER-
MITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
READ ALL INSTRUCTIONS CAREFULLY.
1. The installation of this stove must comply
with your local building code rulings. Please
observe the clearances to combustibles (see
reference figures 3–5). Do not place furni-
ture or other objects within the clearance
area.
2. Verify that the stove is properly installed
before firing the stove for the first time. Af-
ter reading these instructions, if you have
any doubt about your ability to complete
your installation properly, you must obtain
the services of a professional licensed in-
staller familiar with all aspects of safe
and correct installation. DO NOT use
temporary or makeshift compromises
during installation.
3. DO NOT store coal, kindling, flammable
liquids or other combustible materials too
close to the unit. Refer to certification label
on back of unit and reference figures 3 – 5
in this manual.
4. Do not install this stove in a mobile home,
manufactured home, trailer or tent
(NO EXCEPTIONS! per HUD Federal
Standard: 24 CFR Ch.XX).
5. If any parts are missing or defective, please
notify the dealer or manufacturer immediately.
DO NOT OPERATE A STOVE THAT IS
MISSING ANY PARTS!.
6. Do not tamper with combustion air control
beyond normal adjustment capacities.
7. Always connect this stove to a chimney and
vent to the outside. Never vent to another room
or inside a building. DO NOT CONNECT
THIS UNIT TO A CHIMNEY FLUE SERV-
ING ANOTHER APPLIANCE.
8. DO NOT CONNECT a coal burning stove to
an aluminum Type B gas vent. This is not safe.
Use approved masonry or a UL 103 HT (U.S)
Listed Residential Type and Building Heating
Appliance Chimney. Use a 6” diameter chim-
ney or larger, that is high enough to give a good
draft. (See specifics in installation instructions).
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911 Fax: 1-616-396-1971
SENTRY COAL
STOVE
Model VG810CL Owners Manual
(save this manual for future reference)
continued on next page
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - SENTRY COAL

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 1READ ALL INSTRUCTIONS CAREFULLYBEFORE STARTING THE INSTALLATIONOR OPERATING THE STOVE. FAILURETO FOLLO

Page 2

Page 10 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0OPERATING INSTRUCTIONSTHIS STOVE IS DESIGNED TO BURNCOAL FUEL.Chestnut, egg, stove, or nut-size coal

Page 3 - ASSEMBLY INSTRUCTIONS

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 11Fig. 13Thermostat Adjustment AccessOPERATING INSTRUCTIONS continued …4. Add about 15 pounds of coal a

Page 4 - LOCATING STOVE

Page 12 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0RECOMMENDATIONS FOR BURNINGANTHRACITE COAL1. When burning coal, it is important to maintaina clean ch

Page 5 - LOCATING STOVE continued…

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 13CHIMNEY MAINTENANCECREOSOTE – Formation and RemovalWhen coal is burned slowly, it produces tar andoth

Page 6 - CONNECTOR PIPE INSTALLATION

Page 14 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0PART ORDERING – VG810CL SENTRY COAL™ STOVEWhen ordering missing or replacement parts, always give the

Page 7 - CHIMNEY CONNECTIONS

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 15PART ORDERING – VG810CL SENTRY COAL™ STOVEWhen ordering missing or replacement parts, always give the

Page 8 - Continued on next page

Page 16 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0FLOOR PROTECTOR MATERIAL CALCULATIONSThis stove has been tested for and must be installed on a floor

Page 9

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 17A. Brick MasonryMinimum 3.5-inch thick brick masonry all framed intocombustible wall with a minimum o

Page 10 - OPERATING INSTRUCTIONS

Page 18 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0Vogelzang International Corporation400 West 17th StreetHolland, Michigan 49423www.vogelzang.comPhone:

Page 11 - WHEN HEATER IS HOT!

Page 2 / VG810CL SENTRY COAL™ VGZ-011 / 090705.09. Be sure that your chimney is safelyconstructed and in good repair. Have the chim-ney inspected by t

Page 12

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 3Upper Heat ShieldLower Heat ShieldLegAssemblyASSEMBLY INSTRUCTIONSTOOLSPencil6 foot Folding Rule or Ta

Page 13 - CHIMNEY MAINTENANCE

Page 4 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0CAUTION: KEEP FURNISHINGS AND OTHERCOMBUSTIBLE MATERIALS AWAY FROM THESTOVE.LOCATING STOVE1. The stove

Page 14

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 5LOCATING STOVE continued…FLOOR PROTECTOR FLOOR PROTECTORBACKWALLSIDEWALL14"20" 16"18&qu

Page 15

Page 6 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0CONNECTOR PIPE INSTALLATION1. The crimped end of the stovepipe fits insidethe stove flue collar. Insta

Page 16

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 7CHIMNEY CONNECTIONSThe stove must be connected to either a ma-sonry or manufactured metal chimney buil

Page 17

Page 8 / VG810CL SENTRY COAL™ VGZ-011 / 090705.0Fig. 10 - Chimney Construction Through RoofFig. 11 - Chimney Connection to FireboxThrough Masonry Wall

Page 18 - Steve Vogelzang

VGZ-011 / 090705.0 VG810CL SENTRY COAL™ / Page 9CHIMNEY CONNECTIONS continued …a flue liner and make sure it is in good condition.(A flue liner consis